We use cookies to make your experience better.
To comply with the new e-Privacy directive, you agree to the privacy policy and our use of cookies.
Lenovo 01CV830 network card Internal Fiber 16000 Mbit/s
SKU
01CV830
Login for pricing
In stock
Emulex 16Gbps Gen 6 FC Single-Port HBA Adaper for Lenovo System X Servers
Category: Network Cards
Connectivity technology | Wired |
---|---|
Host interface | PCIe |
Interface | Fiber |
Maximum data transfer rate | 16000 Mbit/s |
SKU | 01CV830 |
EAN | 0889488417339 |
Manufacturer | Lenovo |
Availability | Y |
Product Manuals (HTML) |
View Manual View Manual |
PDF URLs |
View PDF |
The Emulex 16 Gb (Generation 6) Fibre Channel (FC) host bus adapters (HBAs) are an ideal solution for all Lenovo System x servers requiring high-speed data transfer in storage connectivity for virtualized environments, data backup, and mission-critical applications. They are designed to meet the needs of modern networked storage systems that utilize high performance and low latency solid state storage drives for caching and persistent storage as well as hard disk drive arrays.
The Emulex 16 Gb Gen 6 FC HBAs feature ExpressLane™, which prioritizes mission-critical traffic in congested networks ensuring maximum application performance on flash storage arrays. They also seamlessly support Brocade ClearLink™ diagnostics through Emulex OneCommand® Manager, ensuring the reliability and management of storage network when connected to Brocade Gen 5 FC SAN fabrics.
The Emulex 16 Gb Gen 6 FC HBAs feature ExpressLane™, which prioritizes mission-critical traffic in congested networks ensuring maximum application performance on flash storage arrays. They also seamlessly support Brocade ClearLink™ diagnostics through Emulex OneCommand® Manager, ensuring the reliability and management of storage network when connected to Brocade Gen 5 FC SAN fabrics.
Ports & interfaces | |
---|---|
Internal | Yes |
PCI version | 3.0 |
Fiber ports quantity | 1 |
Fiber optic connector | FC, SFP+ |
Interface | Fiber |
Host interface | PCIe |
Connectivity technology | Wired |
Bandwidth | |
Full duplex | Yes |
Maximum data transfer rate | 16000 Mbit/s |
Technical details | |
Compatible products | System x3500 M5 Type 5464 System x3550 M5 Type 5463 System x3550 M5 Type 8869 System x3650 M5 Type 5462 System x3650 M5 Type 8871 System x3750 M4 Type 8753 System x3850 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) System x3950 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) NeXtScale nx360 M5 Type 5465 (E5-2600 v3 and E5-2600 v4) |
Product colour | Black, Green, Silver |
Rack mounting | Yes |
Web-based management | Yes |
Hot-swap | Yes |
Hot-Plug support | Yes |
PCI-SIG* SR-IOV Capable | Yes |
Mean time between failures (MTBF) | 10000000 h |
Harmonized System (HS) code | 85176990 |
Quantity per pack | 1 pc(s) |
Compliance certificates | RoHS |
Network | |
Web-based management | Yes |
Maximum operating distance | 150 m |
Full duplex | Yes |
Maximum data transfer rate | 16000 Mbit/s |
Design | |
Compatible products | System x3500 M5 Type 5464 System x3550 M5 Type 5463 System x3550 M5 Type 8869 System x3650 M5 Type 5462 System x3650 M5 Type 8871 System x3750 M4 Type 8753 System x3850 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) System x3950 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) NeXtScale nx360 M5 Type 5465 (E5-2600 v3 and E5-2600 v4) |
Product colour | Black, Green, Silver |
Rack mounting | Yes |
Certification | AS/NZS CISPR22:2009+A1, Class A Australian EMC Framework (RCM) cUR recognized to CSA 22.2, No. 60950-1-07 EN55022:2010, Class A EN55024:2010 EN55032:2012 EU (CE Mark) FCC Rules, Part 15, Class A Industry Canada, ICES-003, Class A Japan VCCI, Class A Korea MSIP, Class A RoHS Compliant (Directive 2011/65/EU) TUV certified to EN60950-1+A11+A1+A12+A2 Taiwan BSMI, Class A UL recognized to UL60950-1 2nd Edition |
Hot-swap | Yes |
Hot-Plug support | Yes |
Internal | Yes |
Mean time between failures (MTBF) | 10000000 h |
LED indicators | Yes |
Rack capacity | 2U |
Component for | Server |
Software | |
Linux operating systems supported | RedHat EL Linux 6.0, RedHat EL Linux 7.0, SuSE Linux 11, SuSE Linux 12.0 |
Other operating systems supported | VMware vSphere ESXi |
Indication | |
LED indicators | Yes |
System requirements | |
Server operating systems supported | Windows Server 2012, Windows Server 2012 R2 |
Linux operating systems supported | RedHat EL Linux 6.0, RedHat EL Linux 7.0, SuSE Linux 11, SuSE Linux 12.0 |
Other operating systems supported | VMware vSphere ESXi |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 55 °C |
Storage temperature (T-T) | -20 - 85 °C |
Operating relative humidity (H-H) | 5 - 95% |
Weight & dimensions | |
Depth | 168 mm |
Height | 69 mm |
Packaging data | |
Low-profile bracket | Yes |
Package type | Box |
Mounting brackets included | Yes |
Quantity per pack | 1 pc(s) |
Packaging content | |
Mounting brackets included | Yes |
Low-profile bracket | Yes |
Package type | Box |
Performance | |
Server operating systems supported | Windows Server 2012, Windows Server 2012 R2 |
Compatible products | System x3500 M5 Type 5464 System x3550 M5 Type 5463 System x3550 M5 Type 8869 System x3650 M5 Type 5462 System x3650 M5 Type 8871 System x3750 M4 Type 8753 System x3850 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) System x3950 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) NeXtScale nx360 M5 Type 5465 (E5-2600 v3 and E5-2600 v4) |
Web-based management | Yes |
Hot-swap | Yes |
Hot-Plug support | Yes |
Linux operating systems supported | RedHat EL Linux 6.0, RedHat EL Linux 7.0, SuSE Linux 11, SuSE Linux 12.0 |
Other operating systems supported | VMware vSphere ESXi |
PCI-SIG* SR-IOV Capable | Yes |
Mean time between failures (MTBF) | 10000000 h |
Certificates | |
Certification | AS/NZS CISPR22:2009+A1, Class A Australian EMC Framework (RCM) cUR recognized to CSA 22.2, No. 60950-1-07 EN55022:2010, Class A EN55024:2010 EN55032:2012 EU (CE Mark) FCC Rules, Part 15, Class A Industry Canada, ICES-003, Class A Japan VCCI, Class A Korea MSIP, Class A RoHS Compliant (Directive 2011/65/EU) TUV certified to EN60950-1+A11+A1+A12+A2 Taiwan BSMI, Class A UL recognized to UL60950-1 2nd Edition |
Logistics data | |
Harmonized System (HS) code | 85176990 |
Other features | |
PCI-SIG* SR-IOV Capable | Yes |
Harmonized System (HS) code | 85176990 |
Quantity per pack | 1 pc(s) |
You may also be interested in
Product |
![]() Popular
Lenovo 01CV830 network card Internal F...
Login for pricing
|
![]() |
![]() Hot Product
QNAP QXG-100G2SF-CX6 network card Inte...
Login for pricing
|
![]() Bestseller
Broadcom BCM957508-P2100G network card...
Login for pricing
|
![]() New
Nvidia ConnectX-6 Dx EN Internal Fiber...
Login for pricing
|
![]() Recommended
Nvidia ConnectX-6 Dx Internal Fiber 10...
Login for pricing
|
---|---|---|---|---|---|---|
SKU |
01CV830
|
QXG-100G2SF-E810
|
QXG-100G2SF-CX6
|
BCM957508-P2100G
|
900-9X6AG-0048-ST0
|
900-9X658-0056-SB1
|
Description |
The Emulex 16 Gb (Generation 6) Fibre Channel (FC) host bus adapters (HBAs) are an ideal solution for all Lenovo System x servers requiring high-speed data transfer in storage connectivity for virtualized environments, data backup, and mission-critical applications. They are designed to meet the needs of modern networked storage systems that utilize high performance and low latency solid state storage drives for caching and persistent storage as well as hard disk drive arrays.
The Emulex 16 Gb Gen 6 FC HBAs feature ExpressLane™, which prioritizes mission-critical traffic in congested networks ensuring maximum application performance on flash storage arrays. They also seamlessly support Brocade ClearLink™ diagnostics through Emulex OneCommand® Manager, ensuring the reliability and management of storage network when connected to Brocade Gen 5 FC SAN fabrics. |
The dual-port QXG-100G2SF-E810 100 GbE network expansion card with Intel® Ethernet Controller E810 supports PCIe 4.0 and provides up to 100Gbps bandwidth to overcome performance bottlenecks. With iWARP/RDMA and SR-IOV support (available soon), the QXG-100G2SF-E810 greatly boosts network efficiency and is ideal for I/O-intensive and latency-sensitive virtualization and data centers. The QXG-100G2SF-E810 is a perfect match for all-flash storage to realize the highest performance potential for ever-demanding IT challenges.
Ensure reliable data transfer with Forward Error Correction (FEC) The QXG-100G2SF-E810 supports FEC to overcome packet loss – a potentially common occurrence in fast, long-distance networks. FEC helps the receiving side detect and recover lost data to correct bit errors, thus ensuring reliable data transmission over “noisy” communication channels. With three FEC modes, you can use a suitable cable and switch to build an optimal network environment. Pair with high-speed switches for high-performance, low-latency data centers The QXG-100G2SF-E810 network expansion card can be connected to a switch either with a QSFP28 cable or a QSFP28 to (4) SFP28 cable. You can also configure network redundancy to achieve network failover via the switch for continuous service and high availability. Unleash the full potential of the NVMe all-flash TS-h2490FU Supporting twenty-four (24) U.2 NVMe Gen 3 x4 SSDs, QNAP’s flagship TS-h2490FU NVMe all-flash storage features a PCIe Gen 4 x16 slot that enables the QXG-100G2SF-E810 to fully realize 100Gbps performance and eliminate bottlenecks in modern data centers, virtualization, cloud applications, and mission-critical backup/restore tasks. Supports Windows and Linux servers/workstations Besides QNAP devices, the QXG-100G2SF-E810 supports many platforms (including Windows 10, Windows Server, and Linux/Ubuntu) allowing you to attain optimal business performance for a wider range of system applications and services. The higher bandwidth density with reduction in links helps reduce cabling footprint and operational costs. |
No
|
36 Months Service (Bring-in)
|
Advanced Networking and Security for the Most Demanding Cloud and Data Center Workloads
NVIDIA® ConnectX®-6 Dx is a highly secure and advanced smart network interface card (SmartNIC) that accelerates mission-critical cloud and data center applications, including security, virtualization, SDN/NFV, big data, machine learning, and storage. ConnectX-6 Dx provides up to two ports of 100Gb/s or a single port of 200Gb/s Ethernet connectivity and is powered by 50Gb/s (PAM4) or 25/10 Gb/s (NRZ) SerDes technology. ConnectX-6 Dx features virtual switch (vSwitch) and virtual router (vRouter) hardware accelerations delivering orders-of-magnitude higher performance than software-based solutions. ConnectX-6 Dx supports a choice of single-root I/O virtualization (SR-IOV) and VirtIO in hardware, enabling customers to best address their application needs. By offloading cloud networking workloads, ConnectX-6 Dx frees up CPU cores for business applications while reducing total cost-of-ownership. |
Dual-Port 100GbE/Single-Port 200GbE SmartNIC
ConnectX-6 Dx SmartNIC is the industry’s most secure and advanced cloud network interface card to accelerate mission-critical data-center applications, such as security, virtualization, SDN/NFV, big data, machine learning, and storage. The SmartNIC provides up to two ports of 100Gb/s or a single-port of 200Gb/s Ethernet connectivity and delivers the highest return on investment (ROI) of any smart network interface card. ConnectX-6 Dx is a member of NVIDIA's world-class, award-winning ConnectX series of network adapters powered by leading 50Gb/s (PAM4) and 25/10Gb/s (NRZ) SerDes technology and novel capabilities that accelerate cloud and data-center payloads. |
Short Description |
Emulex 16Gbps Gen 6 FC Single-Port HBA Adaper for Lenovo System X Servers
|
2x 100G QSFP28, PCIe 4.0 x16
|
Dual port per 100GbE Network adapter; 2 x QSFP28; Mellanox ConnectX-6 Dx controller
|
Dual-Port 100 Gb/s QSFP56 Ethernet PCI Express 4.0 x16 Network Interface Card
|
ConnectX-6 Dx EN adapter card, 200GbE, Single-port QSFP56, PCIe 4.0 x16, Crypto and Secure Boot, Tall Bracket
|
ConnectX-6 Dx EN adapter card, 100GbE, OCP3.0, With Host Management, Dual-port QSFP56, PCIe 4.0 x16, No Crypto, Thumbscrew (Pull Tab) Bracket
|
Manufacturer |
Lenovo
|
QNAP
|
QNAP
|
Broadcom
|
Nvidia
|
Nvidia
|