APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black
SKU
AP8881
Login for pricing
In stock
NetShelter Metered Rack PDU, 0U, 3PH, 11kW 230V 16A or 11kW 230V 16A, 36 C13 and 6 C19 outlets,IEC 309 3P+N+PE cord
Category: Power Distribution Units (PDUs)
AC outlets quantity | 42 AC outlet(s) |
---|---|
SKU | AP8881 |
EAN | 0731304277071 |
Manufacturer | APC |
Availability | Y |
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This 3 phase PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU via IEC 309 3P+N+PE plug with a 1.8m (16 ft) cord while power comes out at 230 volts through (36) C13 and (6) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
Design | |
---|---|
PDU types | Metered |
Mounting | Vertical |
Product colour | Black |
Certification | CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH |
Rack capacity | 0U |
Ports & interfaces | |
AC outlets quantity | 42 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | IEC309 |
Output connections | 36x IEC 320 C13 6x IEC 320 C19 |
Input connection type | IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E |
Features | |
Cable length | 1.83 m |
Certification | CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH |
Management features | |
Monitoring | Current, Power, Voltage |
Ergonomics | |
Cable length | 1.83 m |
Power | |
---|---|
Maximum power | 11000 W |
Nominal input voltage | 400 V |
Nominal output voltage | 230 V |
Maximum current | 16 A |
Maximum total current draw per phase | 16 A |
Maximum input current per phase | 16 A |
Load capacity | 11040 VA |
AC input frequency | 50 - 60 Hz |
Certificates | |
Certification | CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH |
Operational conditions | |
Operating temperature (T-T) | 5 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Weight & dimensions | |
Dimensions (WxDxH) | 56 x 44 x 1791 mm |
Weight | 6.38 kg |
Width | 56 mm |
Depth | 44 mm |
Height | 1791 mm |
Technical details | |
Total carbon footprint (kg of CO2e) | 41106.13 |
Logistics data | |
Total carbon footprint (kg of CO2e) | 41106.13 |
You may also be interested in
Product |
![]() Popular
APC AP8881 power distribution unit (PD...
Login for pricing
|
![]() Bestseller
APC APDU9953 power distribution unit (...
Login for pricing
|
![]() New
Eaton EVMAF116A power distribution uni...
Login for pricing
|
![]() Hot Product
APC AP7822B power distribution unit (P...
Login for pricing
|
![]() Recommended
Eaton EVMAF132X power distribution uni...
Login for pricing
|
![]() |
---|---|---|---|---|---|---|
SKU |
AP8881
|
APDU9953
|
EVMAF116A
|
AP7822B
|
EVMAF132X
|
PE6216G-AX-G
|
Description |
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This 3 phase PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU via IEC 309 3P+N+PE plug with a 1.8m (16 ft) cord while power comes out at 230 volts through (36) C13 and (6) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
|
NetShelter Switched Rack PDUs Features & Benefits
Manageability 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs. Gigabit Ethernet Connectivity 9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity. Network Port Sharing Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series. Multi-tier user access Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements. Outlet Level Grouping Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility. EcoStruxure IT Ready Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere. Enhanced Cybersecurity 9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Adaptability Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment. Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip. Agility Wireless Connectivity Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only - expected to be available on units manufactured after March 2021). Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Availability 60C Operating Temperature Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F). Hydraulic Magnetic Circuit Breakers Provide increased availability by maintaining trip current over a wide temperature range. C13/C15 and C19/C21 Hybrid Outlets Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords. High Retention Outlets With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs. Field-replaceable NMC Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure. |
No
|
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log amperage to support real-time monitoring and historical reporting. This PDU remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. The historical reporting enables users to optimize energy use and plan for capacity with confidence. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 200-230 volts via IEC 309 plug with a 3.6m (11 ft) cord while power comes out at 230 volts through (36) IEC 320 C13 and (6) IEC 320 C19 outlets. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
|
No
|
As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE6216 eco PDU is an intelligent PDU that contains 16 AC outlets and are available in various IEC or NEMA socket configurations.
It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors*. 1x PE6216 eco PDU 1x LIN2-314K-P426 Power Cord 1x Rack Mount Kit 1x CD ROM (Manual, eco Sensors Software) 1x User Instructions |
Short Description |
NetShelter Metered Rack PDU, 0U, 3PH, 11kW 230V 16A or 11kW 230V 16A, 36 C13 and 6 C19 outlets,IEC 309 3P+N+PE cord
|
Rack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 & (3) C19
|
Managed G4 Rack PDU, 22.5U, 3.7 kW, 16 A, 12xC13, 12xC39, 3 m cord
|
NetShelter Metered Rack PDU, 2U, 1PH, 7.4kW 230V 32A, x12 C13 and x4 C19 outlets, IEC 309 cord
|
Managed G4 Rack PDU, 39U, 7.4 kW, 32 A, 24xC13, 18xC39, 3 m cord
|
16-Port Intelligent 0U Power Distribution Unit (PDU), Metered by Bank (2) & Switched by Outlet (14 x C13 & 2 x C19) 16Amp
|
Manufacturer |
APC
|
APC
|
Eaton
|
APC
|
Eaton
|
ATEN
|