PDU 2G, Metered, ZeroU, 23kW, 240V, 32A, 50/60Hz, 30xC13 & 12xC19, 10.1kg, Black
Category: Power Distribution Units (PDUs)
AC outlets quantity | 42 AC outlet(s) |
---|---|
SKU | AP8888 |
EAN | 0731304289944 |
Manufacturer | APC |
Availability | Y |
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Design | |
---|---|
PDU types | Metered |
Mounting | Horizontal/Vertical |
Display | LCD |
Product colour | Black |
Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC-15 A, UL, VCCI A |
Rack capacity | 0U |
Ports & interfaces | |
AC outlets quantity | 42 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Input connection type | IEC 309 60A 3P+N+E |
Features | |
Cable length | 1.83 m |
Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC-15 A, UL, VCCI A |
Ergonomics | |
Cable length | 1.83 m |
Display | LCD |
Power | |
Nominal input voltage | 400 V |
Nominal output voltage | 240 V |
Output voltage | 240 V |
Power protection features | Overload |
Maximum current | 40 A |
Maximum total current draw per phase | 32 A |
Maximum input current per phase | 40 A |
Load capacity | 23000 VA |
AC input frequency | 50 - 60 Hz |
Certificates | |
---|---|
Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC-15 A, UL, VCCI A |
Compliance certificates | RoHS |
Operational conditions | |
Operating temperature (T-T) | 0 - 55 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Weight & dimensions | |
Dimensions (WxDxH) | 56 x 51 x 1829 mm |
Weight | 10.1 kg |
Width | 56 mm |
Depth | 51 mm |
Height | 1829 mm |
Package width | 221 mm |
Package depth | 112 mm |
Package height | 2149 mm |
Package weight | 14.1 kg |
Package dimensions (WxDxH) | 221 x 112 x 2149 mm |
Packaging data | |
Package width | 221 mm |
Package depth | 112 mm |
Package height | 2149 mm |
Package weight | 14.1 kg |
Package dimensions (WxDxH) | 221 x 112 x 2149 mm |
Technical details | |
Total carbon footprint (kg of CO2e) | 72728.29 |
Compliance certificates | RoHS |
Logistics data | |
Total carbon footprint (kg of CO2e) | 72728.29 |
You may also be interested in
Product |
![]() Popular
APC AP8888 power distribution unit (PD...
Login for pricing
|
![]() Hot Product
APC Rack PDU 2G, Metered by Outlet wit...
Login for pricing
|
![]() Bestseller
APC NetShelter Metered Rack PDU, 0U, 3...
Login for pricing
|
![]() Recommended
Vertiv Geist GU30007L power distributi...
Login for pricing
|
![]() |
![]() |
---|---|---|---|---|---|---|
SKU |
AP8888
|
AP8653
|
AP8886
|
GU30007L
|
GU30001L
|
EPDU1232SX3620
|
Description |
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
|
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
|
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
|
OVERVIEW
Upgradeable Switched Outlet Level Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of outlet level power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. With the Geist Upgradeable hot-swap technology, users may easily update the rPDU technology with the addition of the appropriate Interchangeable Monitoring Device (IMD) as business needs change. Benefits Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control. Reliable power distribution with local and remote outlet-level power monitoring options offer quick access to critical power usage information down to the device level to evaluate energy usage trends and maximize uptime. Environmental monitoring capabilities with the addition of optional environmental sensors ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime. Fault-Tolerant Daisy Chaining with RSTP simplifies intelligent rPDU connectivity and ensures data is reported even when a break in the network chain occurs. Supports up to 40 rPDUs. Daisy-chain up to 50 devices on a single IP address and reduce deployment time with self-configuration of downstream devices. |
OVERVIEW
Upgradeable Switched Outlet Level Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of outlet level power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. With the Geist Upgradeable hot-swap technology, users may easily update the rPDU technology with the addition of the appropriate Interchangeable Monitoring Device (IMD) as business needs change. Benefits Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control. Reliable power distribution with local and remote outlet-level power monitoring options offer quick access to critical power usage information down to the device level to evaluate energy usage trends and maximize uptime. Environmental monitoring capabilities with the addition of optional environmental sensors ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime. Fault-Tolerant Daisy Chaining with RSTP simplifies intelligent rPDU connectivity and ensures data is reported even when a break in the network chain occurs. Supports up to 40 rPDUs. Daisy-chain up to 50 devices on a single IP address and reduce deployment time with self-configuration of downstream devices. |
Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the average power strip.
|
Short Description |
PDU 2G, Metered, ZeroU, 23kW, 240V, 32A, 50/60Hz, 30xC13 & 12xC19, 10.1kg, Black
|
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
|
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
|
21xC13, 3xC19, 230V, 3m Cable, 1683x66x51mm, 8.16kg
|
21xC13, 3xC19, 230V, 3m Cable, 1683x66x51mm, 8.16kg
|
EasyPDU, Switched, Zero U, 22 kW, 230V, 30 x C13 & 6 x C19
|
Manufacturer |
APC
|
APC
|
APC
|
Vertiv
|
Vertiv
|
APC
|