We use cookies to make your experience better.
To comply with the new e-Privacy directive, you agree to the privacy policy and our use of cookies.
APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
SKU
AP8653
Login for pricing
In stock
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
Category: Power Distribution Units (PDUs)
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
Design | |
---|---|
Type | Single-phase |
PDU types | Metered, Metered-by-outlet, Switched |
Mounting | Vertical |
Product colour | Black |
Certification | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE |
Rack capacity | 0U |
Ports & interfaces | |
AC outlets quantity | 24 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | IEC309 |
Features | |
Cable length | 3 m |
Certification | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE |
Management features | |
Monitoring | Current, Power, Voltage |
Outlet control | Lock-out, Recycle, Turn off, Turn on |
Ergonomics | |
Cable length | 3 m |
Power | |
Maximum power | 7680 W |
Nominal input voltage | 230 V |
Nominal output voltage | 230 V |
Power protection features | Overload |
Maximum current | 32 A |
Maximum total current draw per phase | 32 A |
Maximum input current per phase | 32 A |
Load capacity | 7680 VA |
AC input frequency | 50 - 60 Hz |
Certificates | |
---|---|
Certification | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE |
Compliance certificates | RoHS |
Operational conditions | |
Operating temperature (T-T) | -5 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Weight & dimensions | |
Dimensions (WxDxH) | 56.00 x 51.00 x 1829.00 mm |
Weight | 8.23 kg |
Width | 56 mm |
Depth | 51 mm |
Height | 1829 mm |
Package width | 162 mm |
Package depth | 118 mm |
Package height | 2038 mm |
Package weight | 10.5 kg |
Package dimensions (WxDxH) | 162.00 x 118.00 x 2038.00 mm |
Packaging data | |
Package width | 162 mm |
Package depth | 118 mm |
Package height | 2038 mm |
Package weight | 10.5 kg |
Package dimensions (WxDxH) | 162.00 x 118.00 x 2038.00 mm |
Technical details | |
Total carbon footprint (kg of CO2e) | 8595.81 |
Compliance certificates | RoHS |
Logistics data | |
Total carbon footprint (kg of CO2e) | 8595.81 |
You may also be interested in
Product |
![]() Hot Product
APC Rack PDU 2G, Metered by Outlet wit...
Login for pricing
|
![]() New
Eaton EVMAF132X power distribution uni...
Login for pricing
|
![]() |
![]() Bestseller
APC NetShelter Metered Rack PDU, 0U, 3...
Login for pricing
|
![]() Recommended
Vertiv Geist rPDU, monitored, 0U, inpu...
Login for pricing
|
![]() Popular
APC Rack PDU 2G, Metered by Outlet wit...
Login for pricing
|
---|---|---|---|---|---|---|
SKU |
AP8653
|
EVMAF132X
|
AP8888
|
AP8886
|
VP8886
|
AP8659
|
Description |
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
|
No
|
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
|
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
|
The Vertiv Geist Monitored Rack PDU VP8886 is a 32A, 230/400V WYE, 0U vertical rack power distribution unit (PDU) with input power monitoring. The VP8886 has (30) IEC C13 and (12) IEC C19 outlets, and a 3P+N+E (IP44) plug providing 22.0kW in power capacity. This Monitored Data Center rPDU provides you quick access to critical power usage information so you can evaluate energy usage trends and maximize uptime. This Monitored Data Center rPDU provides you quick access to critical power usage information so you can evaluate energy usage trends and maximize uptime. The hot-swappable Interchangeable Monitoring Device displays current on the local LED display. Visible Light Communication technology allows you to view complete power usage data locally from a mobile device with the Vertiv rPDU Scanner app. Each rack mount PDU undergoes individual testing for functionality to ensure your network is powered by a reliable smart power strip. The unit comes with a three-year warranty that can be extended to five-years if registered within 120 days of purchase.
|
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
|
Short Description |
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
|
Managed G4 Rack PDU, 39U, 7.4 kW, 32 A, 24xC13, 18xC39, 3 m cord
|
PDU 2G, Metered, ZeroU, 23kW, 240V, 32A, 50/60Hz, 30xC13 & 12xC19, 10.1kg, Black
|
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
|
Vertiv Geist Monitored RPDU – (30) C13 (12) C19| 32A| 230/400V| 3P+N+E (IP44)
|
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19
|
Manufacturer |
APC
|
Eaton
|
APC
|
APC
|
Vertiv
|
APC
|