APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

SKU
AP8886
Login for pricing
In stock
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
More Information
AC outlets quantity 42 AC outlet(s)
SKU AP8886
EAN 0731304289937
Manufacturer APC
Availability Y
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Design
PDU typesMetered
MountingVertical
Product colourBlack
CertificationEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Rack capacity0U
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Output connections30 x IEC 320 C13 12 x IEC 320 C19
Features
Cable length1.83 m
LED indicatorsYes
CertificationEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Management features
MonitoringCurrent, Power, Voltage
Ergonomics
Cable length1.83 m
LED indicatorsYes
Power
Maximum power22000 W
Nominal input voltage400 V
Nominal output voltage230 V
Power protection featuresOverload
Maximum current32 A
Maximum input current per phase32 A
Load capacity22080 VA
AC input frequency50 - 60 Hz
Certificates
CertificationEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Compliance certificatesRoHS
Operational conditions
Operating temperature (T-T)0 - 55 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m
Weight & dimensions
Weight8.72 kg
Width56 mm
Depth51 mm
Height1829 mm
Package width170 mm
Package depth112 mm
Package height2050 mm
Package weight11.6 kg
Packaging data
Package width170 mm
Package depth112 mm
Package height2050 mm
Package weight11.6 kg
Technical details
Total carbon footprint (kg of CO2e)57837.86
Compliance certificatesRoHS
Logistics data
Total carbon footprint (kg of CO2e)57837.86

You may also be interested in

Compare Products
Product APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
Bestseller
APC NetShelter Metered Rack PDU, 0U, 3... Login for pricing
Eaton EVMAF132X power distribution unit (PDU) 42 AC outlet(s) 39U Black
New
Eaton EVMAF132X power distribution uni... Login for pricing
APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
Hot Product
APC Rack PDU 2G, Metered by Outlet wit... Login for pricing
APC AP8888 power distribution unit (PDU) 42 AC outlet(s) 0U Black APC AP8888 power distribution unit (PD... Login for pricing
Vertiv Geist rPDU, monitored, 0U, input IEC60309 230/400V 3x32A, outputs (30)C13 | (12)C19 power distribution unit (PDU) 42 AC outlet(s) Black Vertiv Geist rPDU, monitored, 0U, inpu... Login for pricing
Vertiv Geist GU30007L power distribution unit (PDU) 24 AC outlet(s) 0U Black Vertiv Geist GU30007L power distributi... Login for pricing
SKU
AP8886
EVMAF132X
AP8653
AP8888
VP8886
GU30007L
Description
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
No
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
The Vertiv Geist Monitored Rack PDU VP8886 is a 32A, 230/400V WYE, 0U vertical rack power distribution unit (PDU) with input power monitoring. The VP8886 has (30) IEC C13 and (12) IEC C19 outlets, and a 3P+N+E (IP44) plug providing 22.0kW in power capacity. This Monitored Data Center rPDU provides you quick access to critical power usage information so you can evaluate energy usage trends and maximize uptime. This Monitored Data Center rPDU provides you quick access to critical power usage information so you can evaluate energy usage trends and maximize uptime. The hot-swappable Interchangeable Monitoring Device displays current on the local LED display. Visible Light Communication technology allows you to view complete power usage data locally from a mobile device with the Vertiv rPDU Scanner app. Each rack mount PDU undergoes individual testing for functionality to ensure your network is powered by a reliable smart power strip. The unit comes with a three-year warranty that can be extended to five-years if registered within 120 days of purchase.
OVERVIEW

Upgradeable Switched Outlet Level Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of outlet level power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. With the Geist Upgradeable hot-swap technology, users may easily update the rPDU technology with the addition of the appropriate Interchangeable Monitoring Device (IMD) as business needs change.

Benefits

Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control. Reliable power distribution with local and remote outlet-level power monitoring options offer quick access to critical power usage information down to the device level to evaluate energy usage trends and maximize uptime. Environmental monitoring capabilities with the addition of optional environmental sensors ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime. Fault-Tolerant Daisy Chaining with RSTP simplifies intelligent rPDU connectivity and ensures data is reported even when a break in the network chain occurs. Supports up to 40 rPDUs. Daisy-chain up to 50 devices on a single IP address and reduce deployment time with self-configuration of downstream devices.
Short Description
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
Managed G4 Rack PDU, 39U, 7.4 kW, 32 A, 24xC13, 18xC39, 3 m cord
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
PDU 2G, Metered, ZeroU, 23kW, 240V, 32A, 50/60Hz, 30xC13 & 12xC19, 10.1kg, Black
Vertiv Geist Monitored RPDU – (30) C13 (12) C19| 32A| 230/400V| 3P+N+E (IP44)
21xC13, 3xC19, 230V, 3m Cable, 1683x66x51mm, 8.16kg
Manufacturer
APC
Eaton
APC
APC
Vertiv
Vertiv