APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black
SKU
AP7921B
Login for pricing
In stock
NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 outlets, C20cord
Category: Power Distribution Units (PDUs)
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
Design | |
---|---|
PDU types | Metered, Switched |
Mounting | Horizontal/Vertical |
Product colour | Black |
Certification | cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH |
Rack capacity | 0U/1U |
Ports & interfaces | |
AC outlets quantity | 8 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C20 coupler |
Input connection type | IEC-320 C20 |
Features | |
Cable length | 2.5 m |
Certification | cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH |
Management features | |
Monitoring | Current, Power, Voltage |
Outlet control | Lock-out, Recycle, Turn off, Turn on |
Ergonomics | |
Cable length | 2.5 m |
Power | |
Maximum power | 3680 W |
Nominal input voltage | 200-230 V |
Nominal output voltage | 208-230 V |
Maximum current | 16 A |
Maximum total current draw per phase | 16 A |
Maximum input current per phase | 16 A |
Load capacity | 3680 VA |
AC input frequency | 50 - 60 Hz |
Certificates | |
---|---|
Certification | cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH |
Compliance certificates | RoHS |
Operational conditions | |
Operating temperature (T-T) | 0 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 0 - 95% |
Operating relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 1 - 15000 m |
Weight & dimensions | |
Dimensions (WxDxH) | 445 x 108 x 44 mm |
Weight | 2.27 kg |
Width | 445 mm |
Depth | 108 mm |
Height | 44 mm |
Package width | 470 mm |
Package depth | 343 mm |
Package height | 70 mm |
Package weight | 3.45 kg |
Package dimensions (WxDxH) | 470 x 343 x 70 mm |
Packaging content | |
Packaging content | Installation Guide, Rack Mounting Brackets, User Manual |
Packaging data | |
Package width | 470 mm |
Package depth | 343 mm |
Package height | 70 mm |
Package weight | 3.45 kg |
Package dimensions (WxDxH) | 470 x 343 x 70 mm |
Technical details | |
Total carbon footprint (kg of CO2e) | 915.89 |
Compliance certificates | RoHS |
Logistics data | |
Total carbon footprint (kg of CO2e) | 915.89 |
You may also be interested in
Product |
![]() Bestseller
APC AP7921B power distribution unit (P...
Login for pricing
|
![]() Hot Product
APC AP8853 power distribution unit (PD...
Login for pricing
|
![]() Recommended
APC APDU9953 power distribution unit (...
Login for pricing
|
![]() New
Eaton EVMAF116A power distribution uni...
Login for pricing
|
![]() |
![]() Popular
APC AP8858 power distribution unit (PD...
Login for pricing
|
---|---|---|---|---|---|---|
SKU |
AP7921B
|
AP8853
|
APDU9953
|
EVMAF116A
|
AP8841
|
AP8858
|
Description |
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
|
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
|
NetShelter Switched Rack PDUs Features & Benefits
Manageability 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs. Gigabit Ethernet Connectivity 9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity. Network Port Sharing Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series. Multi-tier user access Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements. Outlet Level Grouping Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility. EcoStruxure IT Ready Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere. Enhanced Cybersecurity 9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Adaptability Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment. Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip. Agility Wireless Connectivity Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only - expected to be available on units manufactured after March 2021). Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Availability 60C Operating Temperature Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F). Hydraulic Magnetic Circuit Breakers Provide increased availability by maintaining trip current over a wide temperature range. C13/C15 and C19/C21 Hybrid Outlets Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords. High Retention Outlets With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs. Field-replaceable NMC Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure. |
No
|
The APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8841 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface. User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access. Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty Enables a quick recovery from overload events and breakers are ultra low profile. Packaging Includes PDU, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable
|
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC C20 inlet (no cord provided) while power comes out at 100-230 volts through (18) C13 and (2) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
|
Short Description |
NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 outlets, C20cord
|
NetShelter Metered Rack PDU, 0U, 1PH, 7.4kW 230V32A, 36 C13 and 6 C19 outlets, IEC 309 2P+E cord
|
Rack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 & (3) C19
|
Managed G4 Rack PDU, 22.5U, 3.7 kW, 16 A, 12xC13, 12xC39, 3 m cord
|
NetShelter Rack PDU, Metered, 0U, 5.0kW 200V and 208V 30A, (36) C13 and (6) C19 outlets
|
NetShelter Metered Rack PDU, 0U, 1PH, 3.3kW 208V 16A or 3.7kW 230V 16A, 18 C13 and 2 C19 outlets, C20 inlet
|
Manufacturer |
APC
|
APC
|
APC
|
Eaton
|
APC
|
APC
|